MTU C23R Instrukcje Operacyjne Strona 51

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 50
4.3 Starting the engine in manual mode
Preconditions
Engine is not under load.
External start interlock is not activated.
DANGER
Unguarded rotating and moving engine components.
Risk of serious injury – danger to life!
Before barring or starting the engine, make sure that nobody is in the danger zone.
WARNING
Engine noise above 85 dB (A).
Risk of damage to hearing!
Wear ear protectors.
Preparation
Item Action
Operating mode switch (if
applicable)
Switch to manual mode.
Coolant preheating unit (if
applicable).
Switch ON.
Starting the engine
Item Action
Switchgear cabinet, opera-
tor station etc. (depending
on manufacturer).
1.
If no coolant preheater is fitted, make sure that the coolant tempera-
ture is > 40 °C.
2.
Press start button.
Automatic starting procedure is performed;
Engine speed instrument indicates increasing speed;
After the starting sequence is completed, engine is running at idle
speed.
M015695/03E 2013-03 | Operation | 51
TIM-ID: 0000002233 - 005
Przeglądanie stron 50
1 2 ... 46 47 48 49 50 51 52 53 54 55 56 ... 162 163

Komentarze do niniejszej Instrukcji

Brak uwag