3 Technical Data
3.1 12/16 V 4000 C13/13R/13L engine data: Application group
5A, optimized fuel consumption
Explanation:
DL Ref. value: Continuous power
BL Ref. value: Fuel stop power
A Design value
G Guaranteed value
R Guideline value
L Limit value, up to which the engine can be operated, without change (e.g. of power setting)
N Not yet defined value
- Not applicable
X Applicable
REFERENCE CONDITIONS
Engine model 12V
4000C13
R
12V
4000C13
12V
4000C13L
16V
4000C13
R
16V
4000C13
16V
4000C13L
Application group 5A 5A 5A 5A 5A 5A
Intake air temper-
ature
°C 25 25 25 25 25 25
Charge-air cool-
ant temperature
°C 45 45 45 45 45 45
Raw-water inlet
temperature
°C - - - - - -
Barometric pres-
sure
mbar 1000 1000 1000 1000 1000 1000
Site altitude
above sea level
m 100 100 100 100 100 100
POWER-RELATED DATA (power ratings are net brake power as per ISO 3046)
Number of cylin-
ders
12V 12V 12V 16V 16V 16V
Rated engine
speed
A rpm 1800 1800 1800 1800 1800
1900
1800
1900
Net brake power
(w/o fan) (fuel
stop power ISO
3046)
A kW 1193 1343 1425 1492 1750 1865
M015695/03E 2013-03 | Technical Data | 25